root@mon39:~# ipmitool -I lanplus -H 192.168.2.46 -U root -P calvin sdr type fan
Fan1A | 30h | ok | 7.1 | 5400 RPM
Fan2A | 32h | ok | 7.1 | 5520 RPM
Fan3A | 34h | ok | 7.1 | 5400 RPM
Fan4A | 36h | ok | 7.1 | 5400 RPM
Fan5A | 38h | ok | 7.1 | 5160 RPM
Fan6A | 3Ah | ok | 7.1 | 5040 RPM
Fan Redundancy | 75h | ok | 7.1 | Fully Redundant
Fan7A | 3Ch | ok | 7.1 | 5160 RPM
Fan1B | 31h | ok | 7.1 | 5160 RPM
Fan2B | 33h | ok | 7.1 | 5160 RPM
Fan3B | 35h | ok | 7.1 | 5040 RPM
Fan4B | 37h | ok | 7.1 | 5160 RPM
Fan5B | 39h | ok | 7.1 | 4800 RPM
Fan6B | 3Bh | ok | 7.1 | 4800 RPM
Fan7B | 3Dh | ok | 7.1 | 4800 RPM
# 关闭自动调节风扇
ipmitool -I lanplus -H 192.168.2.44 -U root -P calvin raw 0x30 0x30 0x01 0x00
# 关闭自动风扇转速,然后设置风扇转速百分比,最后一位0XF是16进制15%转速
ipmitool -I lanplus -U root -P calvin -H 192.168.2.44 raw 0x30 0x30 0x02 0xff 0xf
# 开启自动调节风扇
sudo ipmitool -I lanplus -U root -P calvin -H 192.168.2.44 raw 0x30 0x30 0x01 0x01
ipmi用户名:登录iDRAC的用户名,默认为 root
ipmi密码:登录iDRAC的密码,默认为 calvin,以实际自己设置为准。
服务器地址: iDRAC的服务器IP,不是系统或虚拟机的IP
0x00 代表 禁用 手动调速 ; 0x01 代表 启用 手动调速